cusomer center e - EMAIL to COPY

Request for Quotation

Q&A

Power Sonicator
Carbon Cloth
Carbon Paper
Carbon Felt
´Ù°ø¼º ±Ý¼Ó
Carbon Powder, Liquid
¹æ¿­ Sheet
°í¼Ó¹Ú¸·ºÐ»êÀåºñ
Æú¸®¿Ã·¹ÇÉ
Activated Carbon
Á¤¹Ð È®À强 ±Ý¼Ó
¹èÅ͸® Å×½ºÅͱâ
Laminate Film
ÆÐÅϿµµ Á¶Àý±â
Power Sonicator
WIZ_DBS1500
     Battery Tester
 
Battery Tester
 
Product Descriptions  
 

¡Û Battery Milli-Ohm, Voltage Meter

 

 

1) AX-1242N


Low Cost Battery MILLI OHM/V Meter

- Measures internal resistance such as battery and voltage at the same time

 

Measuring range: 0.00m§Ù~250.0§Ù/DC0.000V~¡¾50.000V
Contact-check is equipped as standard function [Checked each time the contact state of the measuring terminals]
RS-232C interface as standard.

Low-cost general-purpose machine

 

 

 

 

 

 

 

[ Specifications ]

 

- Measuring range and Accuracy (at23¡É¡¾5¡É)

 

 Voltage measuring range 

 Resolution

 Accuracy

 DC0.000V~¡¾50.000V

 1mV

 within ¡¾0.05%rdg¡¾3digit

 Range

 Measuring range

 Resolution

 Measuring current

 Accuracy

 20m§Ù

 0.00m§Ù~25.00m§Ù

 10u§Ù

 100mA

 within

¡¾(0.3%rdg+50u§Ù)

¡¾2digit

 200m§Ù

 0.0m§Ù~250.0m§Ù

 100u§Ù

 10mA

 2m§Ù

 0.000m§Ù~2.500m§Ù

 1m§Ù

 1mA

 20m§Ù

 0.00m§Ù~25.00m§Ù

 10m§Ù

 100uA

 200m§Ù

 0.0m§Ù~250.0m§Ù

 100m§Ù

 10uA

 

 Test signal

 1kHz¡¾0.1% sine wave/applied voltage 1V r.m.s (max.)

 Measuring method

 4~terminal measuring method [available to contact check]

 Sampling time

 [Free running mode] [FAST] 6 times per second [SLOW] 2 times per second

 [Remote start mode] [FAST] 100msec. [SLOW] 450msec.

 Measuring terminals max.

voltage

 DC¡¾50V

 Comparator set range

Resistance : 0000~2500 both high and low limit

Voltage : 00.000~¡¾50.000 both high and low limit

 Indication of comparator¡¯s comparison result

 LED indication LO/GO/HI and buzzer


 Control signal

 Input : Measurement start signal

 Hold signal

 Output : Judgment result signal [R-LO/R-HI/V-LO/V-HI/GO]

 Contact signal error [CE]

 Completion of the measurement signal [EOC]

 Operation condition

 [Temp.] +5¡É~+40¡É   [Humidity] less than 85%

 Power supply

 AC100V/117V/220V/240V selectable, 50/60Hz, about 30VA

 Outer dimension

 about 260(W)¡¿90(H)¡¿250(D) mm (excluding protruding parts such as rubber legs.etc.)

 Weight

 about 2.6kg

 


 

 

[ The Outline ]

 

AX-1242N Battery m§Ù/V meter (Batter iR/OCV tester) inspects to measure internal resistance such as battery having electro motive force and voltage at the same time. Contact-check function as standard equipment: When measure 4 terminals, either one contact failure occurs, outputs Contact Error signal.

 

 

 

 

 

 

 

 

 

 

2) AX-1262B


Battery MILLI OHM/V Meter

- Measures internal resistance such as battery and voltage at the same time

 

Built-in electromotive force cancellation circuit
GP-IB/RS-232C/Centoronics output available. (Option)
4-terminal measurement
Analog Output as standard 

 

 

 

 

 

[ Specifications ]

 

- Measuring range and Accuracy (at23¡É¡¾5¡É)

 

 Voltage measuring range

 Resolution

 Accuracy

 0.000V~12.999V

 1mV

 within ¡¾0.03%rdg¡¾2digit

 Range

 Measuring range

 Resolution

 Measuring current

 Accuracy

 20m§Ù

 0.00m§Ù~19.99m§Ù

 10u§Ù

 100mA

 within

¡¾(0.3%rdg+50u§Ù)

¡¾2digit [Slow]

¡¾3digit [Fast]

 200m§Ù

 0.0m§Ù~199.9m§Ù

 100u§Ù

 10mA

 2m§Ù

 0.000m§Ù~1.999m§Ù

 1m§Ù

 1mA

 20m§Ù

 0.00m§Ù~19.99m§Ù

 10m§Ù

 100uA

 200m§Ù

 0.0m§Ù~199.9m§Ù

 100m§Ù

 10uA


 

 

 Test signal

 1kHz¡¾0.1% sine wave/1V r.m.s (max.)

 Measuring method

 4~terminal measuring method [available to contact check]

 Sampling time

Free running mode : 5 or 15 times/sec.

 Remote start mode : about 24msec./110msec.

 Measuring response time

 Within 20msec. approx.

 Measuring terminals max.

voltage

DC¡¾13V

 Comparator set range

Resistance : 3¨ö Digit (1999) both high and low limit

 

Voltage : 4¨ö Digit (¡¾12.999) both high and low limit

 Indication of comparator¡¯s comparison result

 LED indication LO/GO/HI and buzzer


 Control signal

Remote start signal

 Remote hold signal

 Comparision output [R-LO/R-HI/V-LO/V-HI/GO] : Open-collector output

Contact signal error [CE] : Open-collector output

 end of comparison output [EOC] : Open-collector output

 Analog output

 Resistance value : Full scale DC10V¡¾0.3%¡¾30mV

 Battery voltage : 0~¡¾12V¡¾0.1%¡¾10mV

 Operation condition

 [Temp.] +5¡É~+40¡É   [Humidity] less than 85%

 Power supply

 AC100V/117V/220V/240V selectable, 50/60Hz, about 30VA

 Outer dimension

 333(W)¡¿99(H)¡¿335(D) mm (excluding protruding parts such as rubber legs.etc.)

 Weight

 about 3.5kg

 


 

 

[ The Outline ]

 

AX-1262B Battery m§Ù/V meter inspects to measure internal resistance like battery having electro motive force.

 

Contact check function is standard equipment: When measure 4 terminals, either one contact failure occurs, outputs Contact Error signal.

 

 

 
Top